Dongguan Amade Instruments Technology Co., Ltd
|
Price: | 1000.0 USD |
Payment Terms: | T/T,L/C,WU,Money Gram |
Place of Origin: | Guangdong, China (Mainland) |
![]() |
![]() |
Add to My Favorites | |
HiSupplier Escrow |
Ozone Aging Test Chamber
It is used for determining the cracking resistance of vulcanized or thermoplastic rubbers when subjected to dynamic or static tensile strain exposed at a man-made constant temperature to atmosphere containing given concentration of ozone in conformance.
Standards
JIS K 6259-1
ISO 1431-1
IEC 60811-2-1
GB/T 2951.21 etc
Main Technical Parameters
Test chamber inner dimension | W500XH600XD500mm |
Test chamber Temperature & Humidity | Temperature control range: 0℃~70℃ adjustable Temperature uniformity: +/- 2℃ Humidity control range: 20%RH~90%RH adjustable |
Ozone concentration | 10~1000pphm +/- 10% pphm adjustable |
Ozone gas flow velocity | 12~16mm/s |
Velocity of ozonized air | 600mm/s+/- 100mm/s |
Test time | 0~999H/M/S |
Dynamic testing device | Turnable sample rack stretch frequency: 0.5Hz Sample stretched cyclic between 0 to 10% or other specify stretch ratio Continuous or intermittent dynamic stretching available Sample rack rotating rotates at the specified speed available |
Static test device | After the sample is stretched by 20% or other specified ratio, it is fixed on the sample holder, and the sample holder is rotated at a specific rate to fully expose it to the specified ozone gas. After reaching the predetermined time Observe whether the surface of the sample is cracked |
Sample rack rotating velocity | 20mm~25mm/s or adjustable at will |